고도처리공정에서 다양한 수질에 따른 미량유기오염물질 제거특성 게시글의 제목, 학술지명, 저자, 발행일, 작성내용을 보여줌
고도처리공정에서 다양한 수질에 따른 미량유기오염물질 제거특성
학술지명 한국수처리학회 저자 김충환,권순범,유영범,최양훈
발표일 2015-10-30

Mobile Water Treatment Plant (MWTP) was evaluated for operational parameters, designvalues and especially removal efficiency of taste and odor compounds (T&Os) as organicmicropollutants (OMPs). Geosmin and 2-MIB with a high concentration level i.e., spiked with a range200 ng/L to 1,300 ng/L of initial concentration could be totally removed by MWTP when AOP,O3/GAC, AOP/GAC hybrid process was operated. It found that removal of T&Os by O3 oxidationand GAC adsorption was affected by a several factors i.e., reaction parameters such as initialconcentration and type of organic compounds, water property, especially particulate matters, O3 dosage,retention time.